The IntelliChlor lost communication with the EasyTouch motherboard. First check: cable plugged in and not loose.
Communication between IntelliChlor and the automation panel dropped. Reseat the cable first; cable service may need a pro.
COM LINK ERROR on an EasyTouch panel means the IntelliChlor has lost communication with the EasyTouch motherboard. Usually the cell cable is unplugged or loose; if reseating it doesn't help, Pentair says contact a pool professional to service the cable.
The IntelliChlor lost communication with the EasyTouch motherboard. First check: cable plugged in and not loose.
Power off. Unplug and firmly reseat the cable at the cell and at the automation COM terminal.
Reseat the IntelliChlor cable.
Pentair's first suggested fix is to ensure the cable is plugged in and not loose. Power off, disconnect and reconnect both ends so the connector seats fully, then restore power and re-check Diagnostics.
Look for damage, corrosion, or a stretch that could pull the plug loose.
Inspect the cable path.
Trace the cable from the cell to the panel. Replace a cut, crushed, or green-corroded connector rather than forcing it. A cable under constant tension often works loose again.
Power the automation and salt system back up, then open EasyTouch Diagnostics again.
Cycle power and re-check Diagnostics.
After reseating, restore power and confirm whether COM LINK ERROR has cleared. If it returns immediately with a firmly seated cable, stop DIY work on the board.
Pentair's next step after a seated cable is professional service of the cable.
Call a professional for cable/board service.
Do not probe live RS-485 terminals or replace board chips as a DIY fix. Board-level communication faults and damaged cable runs belong to a qualified technician.
As an Amazon Associate I earn from qualifying purchases. CodeFix earns a commission if you buy through these links, at no extra cost to you.
If the steps above did not clear it, this is the part most people need.
If the connector or cable is damaged, replacing the cable restores communication. Confirm the exact part for your IC20/IC40/IC60 and panel before buying.
No. COM LINK is a communication loss with the EasyTouch motherboard. CHECK FLOW/PCB is a separate IntelliChlor message.
With communication lost to automation, control and status can be wrong even if the cell has power. Fix the link before chasing chemistry.
Reseating a loose cable is a reasonable first check with power off. Cable replacement inside the load center and board work should go to a pro.
Pentair's EasyTouch article: COM LINK ERROR means the IntelliChlor lost communication with the EasyTouch motherboard; ensure the cable is plugged in and not loose, then contact a professional to service the cable if needed.
Source: Pentair: What does COM LINK ERROR mean on my EasyTouch panel? (IntelliChlor Error Messages). Written by a Florida pool service owner. Updated 2026-10-14.